Mobile QR Code QR CODE

REFERENCES

1 
Andreasen L. N. S. , Struijk J. J. , Lawrence S. , 2000, Measurement of the performance of nerve cuff electrodes for recording, Medical and Biological Engineering and Computing, Vol. 38, No. 4, pp. 447-453DOI
2 
Loeb G. E. , Peck R. A. , 1996, Cuff electrodes for chronic stimulation and recording of peripheral nerve activity, Journal of Neuroscience Methods, Vol. 64, No. 1, pp. 95-103DOI
3 
Noller C. M. , Levine Y. A. , Urakov T. M. , Aronson J. P. , Nash M. S. , 2019, Vagus nerve stimulation in rodent models: An overview of technical considerations, Frontiers in Neuroscience, Vol. 13DOI
4 
Yu H. , Xiong W. , Zhang H. , Wang W. , Li Z. , 2014, A cable-tie-type parylene cuff electrode for peripheral nerve interfaces, Proc. of the 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems, pp. 9-12Google Search
5 
Lee S. , Peh W. Y. X. , Wang J. , Yang F. , Ho J. S. , Thakor N. V. , Yen S.-C. , Lee C. , 2017, Toward bioelectronic medicine—Neuromodulation of small peripheral nerves using flexible neural clip, Advanced Science, Vol. 4, No. 11DOI
6 
Rowan C. C. , Graudejus O. , Otchy T. M. , 2022, A microclip peripheral nerve interface ($\mu$cPNI) for bioelectronic interfacing with small nerves, Advanced Science, Vol. 9, No. 3Google Search
7 
Madhvapathy S. R. , Bury M. I. , Wang L. W. , Ciatti J. L. , Avila R. , Huang Y. , Sharma A. K. , Rogers J. A. , 2024, Miniaturized implantable temperature sensors for the long-term monitoring of chronic intestinal inflammation, Nature Biomedical Engineering, Vol. 8, pp. 1040-1052DOI
8 
Lai J. M. , Chieng W. H. , Huang Y.-C. , 1998, Precision alignment of mask etching with respect to crystal orientation, Journal of Micromechanics and Microengineering, Vol. 8, No. 4, pp. 327-329DOI
9 
Walton F. , Cerezo-Sanchez M. , McGlynn E. , Das R. , Heidari H. , 2022, Cleanroom strategies for micro- and nano-fabricating flexible implantable neural electronics, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, Vol. 380, No. 2228DOI
10 
2009, Product Bulletin HD-4100 SeriesGoogle Search
11 
Constantin C. P. , Aflori M. , Damian R.-F. , Rusu R.-D. , 2019, Biocompatibility of polyimides: A mini-review, Materials, Vol. 12, No. 19DOI
12 
Metz S. , Bertsch A. , Renaud P. , 2005, Partial release and detachment of microfabricated metal and polymer structures by anodic metal dissolution, Journal of Microelectromechanical Systems, Vol. 14, No. 2, pp. 383-391DOI
13 
Lazanas A. Ch. , Prodromidis M. I. , 2023, Electrochemical impedance spectroscopy—A tutorial, ACS Measurement Science Au, Vol. 3, No. 3, pp. 162-193DOI
14 
González-González M. A. , Kanneganti A. , Joshi-Imre A. , Hernandez-Reynoso A. G. , Bendale G. , Modi R. , Ecker M. , Khurram A. , Cogan S. F. , Voit W. E. , Romero-Ortega M. I. , 2018, Thin film multi-electrode softening cuffs for selective neuromodulation, Scientific Reports, Vol. 8DOI
15 
Dong C. , Carnicer-Lombarte A. , Bonafè F. , Huang B. , Middya S. , Jin A. , Tao X. , Han S. , Bance M. , Barone D. G. , Fraboni B. , Malliaras G. G. , 2024, Electrochemically actuated microelectrodes for minimally invasive peripheral nerve interfaces, Nature Materials, Vol. 23, pp. 969-976DOI
16 
Cogan S. F. , 2008, Neural stimulation and recording electrodes, Annual Review of Biomedical Engineering, Vol. 10, pp. 275-309DOI
17 
Poppendieck W. , Koch K. P. , Steltenkamp S. , Hoffmann K.-P. , 2009, A measurement set-up to determine the charge injection capacity of neural microelectrodes, World Congress on Medical Physics and Biomedical Engineering, September 7-12, 2009, Munich, Germany, IFMBE Proceedings, Vol. 25/9, pp. 162-165Google Search
18 
Heo D. N. , Kim H.-J. , Lee Y. J. , Heo M. , Lee S. J. , Lee D. , Do S. H. , Lee S. H. , Kwon I. K. , 2017, Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing, ACS Nano, Vol. 11, No. 3, pp. 2961-2971DOI
19 
Thompson S. L. , O'Leary G. H. , Austelle C. W. , Gruber E. , Kahn A. T. , Manett A. J. , Short B. , Badran B. W. , 2021, A review of parameter settings for invasive and non-invasive vagus nerve stimulation (VNS) applied in neurological and psychiatric disorders, Frontiers in Neuroscience, Vol. 15DOI
20 
Lim J. , Lee S. , Jang S. , Cho Y. S. , Kim J. P. , 2025, A sub-50 nW implantable body temperature sensor and its application to a rat, Applied Sciences, Vol. 15, No. 5DOI
21 
2018, Standard Specification for Electronic Thermometer for Intermittent Determination of Patient TemperatureGoogle Search